title: Check state of lmsensors output
agents: linux
author: J.Greiner
license: GPL
description:
 Checks the output of '{sensors}' from the lm_sensors package.
 Note that configuration of alarms can (and should) be configured in the {sensors.conf} file that
 belongs to your lm_sensors installation.

 This is an reimplementation of the lmsensors-check by Wouter de Geus <benv-check_mk@junerules.com>
 (http://notes.benv.junerules.com/lmsensors/)


 Setting the sensors:

 For example if you have a lm85 chip, you can set the min fan speed of fan 2 by adding
 a line in {/etc/sensors.conf} like this:

  chip "lm85-*" "lm85b-*" "lm85c-*" "adm1027-*" "adt7463-*" "adt7468-*" "emc6d100-*" "emc6d102-*"

  set fan2_min 1000

 Or ignore specific checks like this:

  chip "lm85-*" "lm85b-*" "lm85c-*" "adm1027-*" "adt7463-*" "adt7468-*" "emc6d100-*" "emc6d102-*"

  ignore fan2

 You must install the agent plugin lmsensors2 on your machine. By default all chips, which sensors find, are read.

 You can (also) configure, which chips shall be read by setting CHIPS in /etc/check_mk/lmsensors2.cfg.

inventory:
 Each host which provides the section in the check_mk agent gets one Sensor_XXX service per reported sensor.
perfdata:
 One variable: the current sensor value. This can be voltage, fan speed in rpm, temperature (either C or F), so
 make sure to set it to your desired format through sensors.conf